Field study to determine the reliability of HIV viral load results shows minimal impact of delayed testing in South Africa

African Journal of Laboratory Medicine

 
 
Field Value
 
Title Field study to determine the reliability of HIV viral load results shows minimal impact of delayed testing in South Africa
 
Creator Hardie, Diana R. Newman, Howard Reid, Joanna Hsiao, Nei-Yuan van Zyl, Gert Hans, Lucia Odayar, Jasantha Korsman, Stephen
 
Subject HIV viral load testing; diagnostic accuracy study; HIV viral load stability; delayed testing; plasma preparation tubes; high-throughput viral load testing; diagnostic accuracy
Description Background: Understanding factors that impact HIV viral load (VL) accuracy in resource-limited settings is key to quality improvement.Objective: We evaluated whether testing delay and specimen storage between 25 °C and 30 °C before testing affected results.Methods: Between November 2019 and June 2023, 249 individuals on antiretroviral therapy, or with newly diagnosed HIV, were recruited from clinics in Cape Town and Gqeberha, South Africa, and three plasma preparation tubes were collected. One tube was tested within 24 h, while the others were stored uncentrifuged at ambient temperatures before testing. Centrifugation and testing of matched samples were performed on Day 4 and Day 7 after collection.Results: Time delay and ambient storage had minimal impact in specimens with a Day 1 VL of 100 copies/mL. When grouped by Day 1 VL range, 96% – 100% of specimens at Day 4 and 93% – 100% at Day 7 had VLs within 0.5 log copies/mL of the first result. The greatest variability at Days 4 and 7 was observed when the Day 1 VL was 100 copies/mL. However, there was no trend of increasing difference over time. Of Day 1 specimens with undetectable VL, or VL 50 copies/mL, 80% had concordant results at Day 4 and 78% at Day 7.Conclusion: These results show that VL is stable in plasma preparation tubes for 7 days when stored at room temperature. There is significant variability in specimens with low VL, but variability is not affected by testing delay.What this study adds: Ideal HIV VL testing conditions are frequently unachievable in resource-limited settings. Data are needed on whether this impacts on the validity of test results. Our results provide reassurance that storage at ambient temperature for up to 7 days before testing does not substantially affect the VL result.
 
Publisher AOSIS
 
Contributor National Health Laboratory Service, South Africa
Date 2024-05-28
 
Type info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion — prospective; analytical
Format text/html application/epub+zip text/xml application/vnd.openxmlformats-officedocument.spreadsheetml.sheet application/pdf
Identifier 10.4102/ajlm.v13i1.2364
 
Source African Journal of Laboratory Medicine; Vol 13, No 1 (2024); 6 pages 2225-2010 2225-2002
 
Language eng
 
Relation
The following web links (URLs) may trigger a file download or direct you to an alternative webpage to gain access to a publication file format of the published article:

https://ajlmonline.org/index.php/ajlm/article/view/2364/2891 https://ajlmonline.org/index.php/ajlm/article/view/2364/2892 https://ajlmonline.org/index.php/ajlm/article/view/2364/2893 https://ajlmonline.org/index.php/ajlm/article/view/2364/2895 https://ajlmonline.org/index.php/ajlm/article/view/2364/2894
 
Coverage South Africa — public sector
Rights Copyright (c) 2024 Diana R. Hardie, Howard Newman, Joanna Reid, Nei-Yuan Hsiao, Gert van Zyl, Lucia Hans, Jasantha Odayar, Stephen Korsman https://creativecommons.org/licenses/by/4.0
ADVERTISEMENT