Development of a flow cytometric bead immunoassay and its assessment as a possible aid to potency evaluation of enterotoxaemia vaccines
Journal of the South African Veterinary Association
Field | Value | |
Title | Development of a flow cytometric bead immunoassay and its assessment as a possible aid to potency evaluation of enterotoxaemia vaccines | |
Creator | Buys, Angela Macdonald, Raynard Crafford, Jannie Theron, Jacques | |
Description | Enterotoxaemia, an economically important disease of sheep, goats and calves, is caused by systemic effects of the epsilon toxin produced by the anaerobic bacterium Clostridium perfringens type D. The only practical means of controlling the occurrence of enterotoxaemia is to immunise animals by vaccination. The vaccine is prepared by deriving a toxoid from the bacterial culture filtrate and the potency of the vaccine is tested with the in vivo mouse neutralisation test (MNT). Due to ethical, economic and technical reasons, alternative in vitro assays are needed. In this study an indirect cytometric bead immunoassay (I-CBA) was developed for use in vaccine potency testing and the results were compared with those obtained using an indirect enzyme-linked immunosorbent assay (I-ELISA) and the MNT. Sera were collected from guinea pigs immunised with three different production batches of enterotoxaemia vaccine and the levels of anti-epsilon toxin antibodies were determined. Although the intra- and inter-assay variability was satisfactory, epsilon antitoxin levels determined by both the I-ELISA and indirect cytometric bead immunoassay (I-CBA) tests were higher than those of the MNT assay. In contrast to the MNT, all of the serum samples were identified as having antitoxin levels above the required minimum (not less than 5 U/mL). These results indicate that the respective in vitro tests in their current formats are not yet suitable alternatives to the in vivo MNT. The growing demand for a more humane, cost-effective and efficient method for testing the potency of enterotoxaemia vaccines, however, provides a strong impetus for further optimisation and standardisation of the I-CBA assay but further analytical research is required. | |
Publisher | AOSIS | |
Date | 2014-03-10 | |
Identifier | 10.4102/jsava.v85i1.977 | |
Source | Journal of the South African Veterinary Association; Vol 85, No 1 (2014); 6 pages 2224-9435 1019-9128 | |
Language | eng | |
Relation |
The following web links (URLs) may trigger a file download or direct you to an alternative webpage to gain access to a publication file format of the published article:
https://jsava.co.za/index.php/jsava/article/view/977/1358
https://jsava.co.za/index.php/jsava/article/view/977/1359
https://jsava.co.za/index.php/jsava/article/view/977/1360
https://jsava.co.za/index.php/jsava/article/view/977/1357
|
|
ADVERTISEMENT