Validation of the Coaguchek® XS INR point-of-care analyser to monitor the INR of patients at Windhoek Central Hospital, Namibia

African Journal of Laboratory Medicine

 
 
Field Value
 
Title Validation of the Coaguchek® XS INR point-of-care analyser to monitor the INR of patients at Windhoek Central Hospital, Namibia
 
Creator Thikukutu, Moses M. Jonkman, Lauren J. Singu, Bonifasius S. Mubita, Mwangana Verbeeck, Roger K.
 
Subject Anticoagulation; Point of care testing; warfarin CoaguChek® XS INR meter; Beckman Coulter ACL 7000 automated coagulometer; sensitivity; specificity; clinical concordance
Description Background: The use of point-of-care INR (international normalised ratio) testing is on the rise because of its ability to facilitate quick clinical decisions as it allows for rapid turnaround time of INR results. Ensuring the quality of these tests is crucial when implementing them in new settings.Objective: This study aimed to assess the sensitivity, specificity, and clinical agreement between the CoaguChek® XS INR meter and the Beckman Coulter ACL 7000 automated coagulometer in outpatients undergoing warfarin therapy.Methods: A prospective cohort design was employed for this comparison. The analysis included Spearman’s correlation, a Bland-Altman plot, and a Cohen’s Kappa analysis of paired INR values. Key outcome measures included the percentage sensitivity, specificity, and clinical agreement of the two methods. A p-value 0.05 was considered statistically significant.Results: The study involved 89 patients, predominantly female (59.4%), with a mean age of 46 years. Deep vein thrombosis was the most common indication for warfarin therapy (51.9%). The mean difference between INR values determined by the two methods was –0.15 (± 0.27, N = 89), and the Spearman rank correlation coefficient was 0.97 (p  0.001, N = 89). A clinical agreement of 83.8% (p  0.05) was obtained. The sensitivity was 94.4%, with specificities of 82.5% for subtherapeutic and 100% for supratherapeutic INRs.Conclusion: The CoaguChek® XS INR meter was proven to be a reliable alternative to the Beckman Coulter ACL 7000 automated coagulometer for monitoring INR results and adjusting warfarin therapy in well-trained patients with stable INR values.What this study adds: The CoaguChek® XS INR meter was proven to be a reliable alternative to the Beckman Coulter ACL 7000 automated coagulometer for monitoring INR results.
 
Publisher AOSIS
 
Contributor None
Date 2026-07-23
 
Type info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion — Prospective Cohort study
Format text/html application/epub+zip text/xml application/pdf
Identifier 10.4102/ajlm.v15i1.3023
 
Source African Journal of Laboratory Medicine; Vol 15, No 1 (2026); 6 pages 2225-2010 2225-2002
 
Language eng
 
Relation
The following web links (URLs) may trigger a file download or direct you to an alternative webpage to gain access to a publication file format of the published article:

https://ajlmonline.org/index.php/ajlm/article/view/3023/3564 https://ajlmonline.org/index.php/ajlm/article/view/3023/3565 https://ajlmonline.org/index.php/ajlm/article/view/3023/3566 https://ajlmonline.org/index.php/ajlm/article/view/3023/3567
 
Coverage Sub-Saharan Africa — average 49 years; 59.4% female; mixed ethnicity
Rights Copyright (c) 2026 Moses M. Thikukutu, Lauren J. Jonkman, Bonifasius S. Singu, Mwangana Mubita, Roger K. Verbeeck https://creativecommons.org/licenses/by/4.0