Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria

Journal of the Colleges of Medicine of South Africa

 
 
Field Value
 
Title Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria
 
Creator Seema, Mmatlou D. Dehghan-Dehnavi, Alireza Lowane, Hanyani
 
Subject Diagnostic Radiology; Interventional Radiology; Interventional Neuroradiology diagnostic reference level; kerma air product; fluoroscopy time; interventional radiology; interventional neuroradiology; radiation dose optimisation.
Description Background: The rising demand for interventional radiology procedures (IRPs) performed under fluoroscopic guidance increases the risk of harmful radiation effects for patients and staff. Radiation dose optimisation using diagnostic reference levels (DRLs) is necessary to keep radiation ‘as low as reasonably achievable (ALARA)’. Establishment of DRLs is required for radiation imaging centres; however, only a few have published them in South Africa. This study aimed to establish local diagnostic reference levels (LDRLs) for IRPs and compare them with DRLs of local and international imaging centres.Methods: A retrospective descriptive study was conducted at a single imaging centre. The IRPs performed on adults between 01 January 2023 and 31 December 2023 were considered. Ethical clearance was obtained before data collection. Data on fluoroscopy time (FT) and kerma air product (KAP) were obtained from a procedure register book. The third quartile (75th percentile) of the dataset for KAP and FT of every IRP indicated the LDRLs.Results: A total of 375 IRPs were analysed. The most frequently performed IRP was cerebral interventions (21%, n = 80). Aortic interventions recorded the highest dose LDRL (KAP = 252.5 Gy/cm2), followed by cerebral interventions (KAP = 211.3 Gy/cm2). Cerebral interventions recorded the longest FT (56.8 min), followed by aortic interventions (36.2 min), both of which exceeded the local centres’ DRL ranges. Permanent catheterisation (KAP = 10.7 Gy/cm2) also exceeded the international DRL range.Conclusion: Established LDRLs for IRPs were mostly within local and international DRL ranges.Contribution: The study contributed to the establishment of local, national and regional DRLs, which assisted imaging centres in optimising radiation doses for IRPs.
 
Publisher AOSIS
 
Contributor —
Date 2026-04-21
 
Type info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion — Retrospective; quantitative; descriptive study
Format text/html application/epub+zip text/xml application/pdf
Identifier 10.4102/jcmsa.v4i1.279
 
Source Journal of the Colleges of Medicine of South Africa; Vol 4, No 1 (2026); 8 pages 2960-110X 3105-4331
 
Language eng
 
Relation
The following web links (URLs) may trigger a file download or direct you to an alternative webpage to gain access to a publication file format of the published article:

https://jcmsa.org.za/index.php/jcmsa/article/view/279/990 https://jcmsa.org.za/index.php/jcmsa/article/view/279/991 https://jcmsa.org.za/index.php/jcmsa/article/view/279/992 https://jcmsa.org.za/index.php/jcmsa/article/view/279/993
 
Coverage South Africa; Gauteng province; Pretoria January 2023-December 2023 Age; Sex; Kerma air product; Fluoroscopy time
Rights Copyright (c) 2026 Mmatlou D. Seema, Alireza Dehghan-Dehnavi, Hanyani Lowane https://creativecommons.org/licenses/by/4.0
ADVERTISEMENT